Fabricant de cordons à fibre optique
HENGXANG assemble et teste des cordons, pigtails et harnais MPO/MTP à Yiwu : LC, SC, FC, ST, MU, E2000 et MPO/MTP sur fibre G.652D, G.657A1/A2 et OM1-OM5.
Chaque cordon passe un test 100% IL/RL sur banc - la mesure figure sur l’étiquette. MOQ dès 100 pièces, expédition en 3-6 jours.
Codage à votre marque de switch sur demande : Cisco, HPE, Huawei, etc.
Fiber Patch Cord & Pigtail Products
What We Build: Specs, MOQ and Lead Time by Family
Three numbers decide most purchase orders: what you can order, how many, and how fast it lands. The table lists every patch cord family this fiber patch cord manufacturer assembles in its own workshop. Lead time counts from deposit and includes 100% testing and packing.
| Cord family | Build | Length | MOQ | Lead time |
|---|---|---|---|---|
| Simplex / duplex single-mode (LC, SC, FC, ST) | G.652D / G.657A1, UPC or APC, 0.9-3.0 mm, PVC or LSZH | 0.3-30 m | 100 pcs | 3-6 days |
| Multimode duplex (OM1-OM5) | 50/125 and 62.5/125, aqua / lime / orange jackets | 0.3-30 m | 100 pcs | 3-6 days |
| Pigtails 0.9 mm | SC, LC, FC, ST - UPC or APC, single-mode | 0.5-2 m | 200 pcs | 3-5 days |
| MPO / MTP trunk cable | 8-72 fibers, OS2 / OM3 / OM4, polarity A, B or C, male / female | 0.5-30 m | 20 pcs | 6-10 days |
| MPO-LC / MPO-SC fanout harness | Cassette-ready 0.9 mm legs, 8-24 fibers | 0.35-5 m | 20 pcs | 6-10 days |
| Armored patch cords | Spiral steel armor, LSZH jacket, LC-LC and mixed types | 0.5-10 m | 100 pcs | 4-7 days |
| FTTH jumpers | 1.6-2.0 mm drop-style, SC/APC and mixed heads | 1-5 m | 200 pcs | 4-6 days |
| Outdoor duplex branch cable | MDPE jacket, pre-made long runs to 100 m | 10-100 m | 100 pcs | 5-8 days |
MOQ and lead-time figures are standard production windows; peak season around Chinese New Year can add 5-7 days. Fixed delivery dates are confirmed in writing on the proforma invoice.
What buyers order most from this shelf
- LC-LC duplex single-mode, 3 m: the data center staple - yellow jacket, UPC or APC, stocked for same-week dispatch.
- MPO-12 OM4 trunks, polarity B: 40/100G backbone builds, aqua jacket, male or female to match the cassettes.
- SC/APC pigtails, 1 m: FTTH closures and boxes - the workhorse of last-mile rollouts.
- Armored LC-LC cords: factory floors and ceiling routes where standard jackets get cut.
- MPO to LC fanouts: break 40G ports into 10G service ports without a new panel.
These five SKUs cover most purchase orders we ship. Your mix may differ - the full shelf sits in the product grid above, and everything on it builds to your length and label.
Cords can arrive pre-loaded into termination boxes, cassettes or ODF panels - factory-loaded panels cut on-site assembly to plug and label. For the raw cable behind every cord, see our fiber optic cable range, all drawn from the same plant.
UPC or APC? Pick the Polish by the Link, Not by Habit
The polish decides the return loss, and the return loss decides whether a link runs clean. Here is how this fiber patch cord manufacturer guides the choice:
| UPC | APC | |
|---|---|---|
| Polish angle | Near 0 degrees | 8 degrees |
| Connector color | Blue | Green |
| Return loss (single-mode) | ≥50 dB | ≥60 dB |
| Best for | LAN, data center port counts, general patching | FTTH/RF-over-glass, DWDM, long-haul and high-gain links |
| Rule | Never mate UPC into APC - the angle mismatch damages both ferrules and spikes the loss | |
FTTH builds in Asia and the Middle East run SC/APC at the ONT almost everywhere; data centers stay UPC on OM4 and OS2 patching. When one site mixes both, we color-split the labels so installers never grab the wrong bag. Tell us the equipment side - we flag conflicts before you order.
MPO Polarity A, B and C: Getting It Right the First Time
MPO links fail on polarity more than on loss. The fibers inside a 12-fiber trunk must line up transmit-to-receive at both ends, and three standards describe how:
- Method A: straight-through - key-up to key-down; the flip happens in the cassette. Simplest for mixed vendor sites.
- Method B: reversed at one end - key-up to key-up; the trunk itself flips the array. Common in pure data center deployments.
- Method C: pair-wise flip inside the trunk - used in some legacy designs.
Send us the cassette model and the port plan - a photo of the panel is enough. We build and label the trunks to your method, male or female pins, and state the polarity on every label. MPO assembly runs in a separate cell with its own interference and geometry checks, so a 72-fiber trunk carries the same paperwork as a simplex cord.
Uniboot and High-Density Options for Packed Racks
When a 1U panel holds 48 ports, cable bulk becomes the enemy. Our high-density options cut the clutter:
- Uniboot LC: the two legs share one round cable and split at the last 30 cm; a push-pull tab lets techs unplug in zero clearance. Available in 2.0 mm and 3.0 mm.
- Reduced-diameter 1.6 mm jackets: half the bend volume of 3.0 mm cable in the same tray.
- Length-matched rack sets: cords cut to your rack elevation plan, bagged per position number - installers hang cables instead of coiling them.
- Color routing: boot colors assigned by function (OS2 blue, OM4 aqua, storage violet) so a mis-patch is visible from two meters away.
These options are OEM territory: send the rack elevation, and this fiber patch cord manufacturer returns a length schedule with the quoted set.
Quality You Can Read From the Data Sheet
A patch cord is a test result, not a product photo. These are the numbers we build and test to, batch after batch:
- Insertion loss: ≤0.3 dB typical, ≤0.5 dB maximum per connector pair, measured at 1310/1550 nm single-mode and 850/1300 nm multimode.
- Return loss: ≥50 dB single-mode UPC, ≥60 dB APC, ≥20 dB multimode.
- Durability: ≤0.2 dB change after 500 mating cycles (design test), zirconia ceramic ferrules on every connector we assemble.
- End face: inspected to IEC 61300-3-35 scope classes before assembly; dusty ferrules never reach the bench.
- Testing: 100% of cords - not samples - pass IL and RL on calibrated benches, and the reading prints on the label.
Failure rates on standard cords run well under 0.1% in our shipment records (draft figure - confirm with sales). When a cord is good, the label proves it; when a claim happens, the same label settles it.
Pigtail or Patch Cord? Match the Product to the Joint
Both start as the same fiber - the difference is one connector versus two, and it changes how your crew works:
| Pigtail (one connector) | Patch cord (two connectors) | |
|---|---|---|
| Where it goes | Spliced onto cable ends, inside closures, boxes and ODFs | Plugged between panels, ONTs and equipment ports |
| Cable style | 0.9 mm buffered fiber | 1.6-3.0 mm jacketed zip or simplex |
| Field skill needed | Fusion splicer and a trained jointer | None - plug and label |
| Best economics | High-count terminations (48+ ports per frame) | Moves, adds and changes; equipment patching |
Most networks use both: pigtails at the frame, patch cords between frames. Ordering both from one fiber patch cord manufacturer keeps the connector geometry consistent, so a pigtail spliced today mates with a cord bought next year at the same loss.
How to Read Our Test Labels and Batch Files
The label is the warranty. Every cord from this fiber patch cord manufacturer carries a label with the connector types, fiber grade, length, and the measured IL and RL values from its own bench pass. Batch files follow the same fields so your QA team can sort and audit:
- Per-cord label: SKU code, connector pair, fiber, length, IL and RL readings, batch number.
- Batch file: a spreadsheet (CSV or Excel) with one row per cord - your asset system can import it directly.
- Custom formats: we export to your template, including barcode and QR label layouts, above 1,000 pieces at no cost.
- Retained samples: every batch keeps control samples for the warranty period, so any later claim is re-tested against the same lot.
Procurement teams tell us the test file shortens acceptance meetings to minutes: the installer plugs in, the meter matches the label, the batch signs off.
Connector and Naming Decoder for Buyers
Procurement teams read datasheets faster with this decoder - it covers every code on our quotation sheets:
| Code | Meaning | Where you see it |
|---|---|---|
| LC | Small form factor latch connector, 1.25 mm ferrule | Data centers, SFP ports |
| SC | Push-pull square connector, 2.5 mm ferrule | FTTH ONTs, media converters |
| FC | Screw-on metal connector | Test gear, older telecom racks |
| ST | Bayonet metal connector | Legacy campus backbones |
| MU / E2000 | Compact and shielded-ferrule types | Dense panels, European telecom |
| MPO / MTP | Multi-fiber push-pull, 8-72 fibers | 40/100G links, MDC cassettes |
| UPC / APC | Ultra / angled physical contact polish - blue / green | Jacket and connector colors |
| OS2 / OM1-OM5 | Single-mode and multimode fiber grades | Jacket colors: yellow, aqua, lime, orange |
| Simplex / duplex / uniboot | Single strand, zip-cord pair, round leg with pull-tab | High-density rack builds |
Send a drawing with any code you do not see here - our workshop builds hybrid and special heads, such as transceiver-side conversions and mode-conditioning cords, on request.
OEM, ODM and Private-Label Capability
As an OEM fiber patch cord manufacturer we build to your drawing, your colors and your label. Three service levels cover most buyers:
- OEM: your logo on labels, bags and cartons; boot and jacket colors mixed per line item; free label printing above 500 pieces.
- ODM: custom assemblies - uniboot, length-specified rack sets, hybrid heads, mode-conditioning cords - engineered and sample-tested before volume.
- OBM / JDM: exclusive part numbers and stocking programs for distributors, with signed NDAs and locked pricing per season.
OEM projects we shipped (draft references - replace with your approved cases)
- European colocation data center, 2024: 12,000 MPO-12 OM4 trunk and fanout cords, polarity B, aqua jackets, shipped in 4 phases against a rack-installation schedule.
- US FTTH installer, 2023: 30,000 SC/APC pigtails with private labels and per-bag barcodes, delivered in 6 weekly call-offs.
- India campus network, 2025: 8,600 LC-LC duplex OM3 cords plus 1,200 armored LC-LC cords for a factory-floor retrofit with metal-dust exposure.
“Every bag carried a test label that matched our asset system. Zero re-terminations across the whole fit-out.” - project manager, European data center contractor (draft testimonial - replace with your approved reference).
“They held the color and length spec across six batches, and the MPO polarity was right the first time.” - purchasing lead, US fiber installer (draft testimonial - replace with your approved reference).
Patching into splitters or WDM points? Buyers commonly pair cords with our PLC splitters, adapters and fast connectors in the same container, so one purchase order covers the whole rack.
Wholesale and Distributor Program
Distributors live on stock turn and clean paperwork. The wholesale program at this fiber patch cord manufacturer runs on five rules:
- Mixed-SKU containers: cords, pigtails, MPO trunks and adapters share one container with tiered pricing at 5,000, 20,000 and 50,000 pieces per cycle.
- Call-off stocking: frame agreements reserve production slots; you draw stock monthly without re-quoting.
- Price protection: quoted project prices hold for 30 days.
- Direct-ship option: we ship sealed sub-cartons straight to your project sites under your labels.
- Marketing kit: factory photos, certificates and test-report templates for your own tender files.
New distributors start with a trial mixed order and scale to frame terms once the return rate proves itself - most stay on call-off terms within two cycles.
Warranty, After-Sales and How Claims Settle
After-sales is where trading companies go quiet and factories stay answerable. Our policy runs on three commitments:
- Warranty window: standard cords carry a replacement warranty against factory faults (term confirmed on the proforma - typically 12-24 months).
- Data-first claims: a claim needs the batch label and your field reading; our bench re-tests the same batch from retained samples and answers with numbers.
- Fast replacement: confirmed faults ride the next production run free - most replacements ship within 10 days of the agreed claim.
Retained samples from every batch stay on the shelf for the warranty period, so a dispute never turns into opinion versus opinion. It is one reason repeat buyers treat this fiber patch cord manufacturer as a long-term extension of their own warehouse.
Certifications and Test Compliance
Every cord inherits the factory's quality system. The plant runs under ISO 9001:2015, our CE paperwork covers the connector families sold into the EU, and our R&D director holds the utility patent on a fiber optic quick connector. The documents are public on the certificate page.
| Certificate | Relevance to your cords |
|---|---|
| ISO 9001:2015 | Quality management for assembly, test and shipment of optical products |
| OHSAS 18001:2007 | Occupational health and safety management |
| CE reports | Connector families shipped into the EU |
| Utility model patent | Fiber optic quick connector, inventor Zhou Liubo - the same bench team assembles your cords |
Compliance references: connector optical performance measured per IEC 61300 test sequences, end-face cleanliness to IEC 61300-3-35, and RoHS-compliant jacket materials on request. Certificate copies ride with every quotation.
Factory Strength: The Workshop Behind the Label
Cords are only as good as the bench that tested them. Our assembly workshop sits inside the same Yiwu compound where we extrude cable - 25 years of fiber work under founder LING LI, started December 2000:
- Assembly lines: dedicated epoxy-polish and quick-termination lines for simplex, duplex and 0.9 mm pigtail work; separate MPO/MTP cell with its own polarity and interference checks.
- Test benches: calibrated IL/RL testers run every cord; 3D interferometer sampling guards ferrule geometry (draft detail - confirm current instrument list with sales).
- Quality team: Grace Xu, Quality Director, owns the release step - no batch ships without her sign-off on the test sheet.
- R&D: Zhou Liubo, Director of R&D and patent holder, designs the special heads and uniboot conversions.
- Export desk: Peter Lin, Head of Export Sales, one named contact per buyer from RFQ to B/L. Video walk-throughs of the workshop run on request - see the factory gallery.
Because assembly, cable extrusion and packing share one compound, a mixed order of cords plus bulk cable leaves on one truck to Ningbo or Shanghai port.
| Company quick facts | |
|---|---|
| Founded | December 2000, Yiwu City, Zhejiang, China |
| Founder | LING LI, Founder & General Manager |
| Focus | Fiber patch cords, pigtails, MPO/MTP harnesses, cable, connectors, splitters, ODFs |
| Export markets | 40+ countries across Asia, the Middle East, Africa, Europe and the Americas |
| Response time | Quotes within 24 hours on business days |
Why Buyers Pick HENGXANG Over Other Suppliers
Compare suppliers on the points that decide project outcomes, not brochure adjectives:
| Factor | HENGXANG | Typical trading company |
|---|---|---|
| Testing | 100% IL/RL, reading on each label | Batch sampling, no per-cord data |
| MOQ | 20-200 pcs by family; trial lots welcome | 1,000 pcs minimums per type |
| Connector range | LC, SC, FC, ST, MU, E2000, MPO/MTP in one order | 2-3 common types only |
| Quote speed | Within 24 hours on business days | Days, forwarded to a third factory |
| Mixed orders | Cords + cable + splitters + ODFs, one container | Single category |
| Traceability | Batch label + per-cord test reading + fiber lot | Box label only |
| Factory access | Live video audits and third-party inspection welcome | Rarely allowed |
And one habit that wins tenders: we quote what your rack actually needs. If a duplex cord should be uniboot for a packed patch panel, the quote says so before you order the wrong build.
How We Work With You: From BOM to Delivered Cartons
Six steps, all in writing, one contact:
- Step 1 - RFQ: send the BOM - connector types, fiber grade, lengths, quantities. WhatsApp +86 134 3434 9304 or the contact form.
- Step 2 - Quote: unit prices by SKU, MOQ, lead time and packing plan within 24 hours on business days.
- Step 3 - Samples: sample cords ship in 3-5 days for your lab bench or site trial.
- Step 4 - Assembly: after deposit, production photos at polish, assembly and test stages.
- Step 5 - Inspection: 100% IL/RL bench plus your third-party inspector if required.
- Step 6 - Shipment: EXW, FOB Ningbo/Shanghai or CIF; documents within 3 working days of vessel departure.
Between orders, the same desk answers technical questions - and our FAQ page covers the common ones in plain language.
Worked Example: A 2,000-Piece Mixed Order, Start to Seal
Numbers beat adjectives. Here is a typical mixed project (illustrative figures - your quote states yours): 1,200 LC-LC duplex single-mode cords at 3 m, 500 SC/APC pigtails, and 300 MPO-12 OM4 trunks at 5 m for one data hall:
| Step | Detail |
|---|---|
| Day 0 | BOM received by WhatsApp; quote issued next morning with tier pricing |
| Day 1-2 | Samples pulled from stock and airfreighted for approval |
| Day 3-8 | Assembly: pigtails first, then cords, then MPO trunks; labels printed to the buyer's asset code format |
| Day 8-9 | 100% IL/RL on all 2,000 pieces; test file exported to the buyer's format |
| Day 10 | Carton pack: 40 cartons, desiccant, barcode labels; 14 cbm total - fits half a 20 ft container |
| Day 11 | Trucked to Ningbo, FOB; B/L and test file issued 2 days after sailing |
Eleven days from BOM to sealed cartons - that is the pace of a factory that assembles, tests and packs under one roof, and the reason buyers treat this fiber patch cord manufacturer as a stockroom extension rather than a vendor.
Build the Whole Link, Not Just the Cords
Cords land the signal, and the rest of the passive chain comes from the same plant: bulk cable for the routes, connector components for field assembly, adapters and termination boxes for the panels, splitters for the split points, and ODFs for the central office. New to ODF planning? Our ODF planning guide maps port counts to rack layouts in plain language. One supplier, one freight plan, one warranty conversation.
Frequently Asked Questions
What is your MOQ for fiber patch cord orders?
Standard simplex and duplex cords start at 100 pieces per type, pigtails at 200 pieces, and MPO/MTP trunks at 20 pieces. First-time buyers can order below MOQ for a live trial project. As a flexible fiber patch cord manufacturer we also mix lengths, colors and connector types inside one production run.
How fast can you deliver a patch cord order?
Standard LC, SC, FC and ST cords ship in 3-6 days, pigtails in 3-5 days, and MPO/MTP trunks or fanouts in 6-10 days. Orders above 10,000 pieces run on a production plan we confirm in writing with the proforma invoice.
Do your patch cords come with test reports?
Yes. Every cord passes 100% insertion loss and return loss testing before packing. You receive the test data with the shipment - per cable or per batch label, in the format your QA team prefers. Claims never argue about data because every cord carries its own numbers.
What is the difference between UPC and APC connectors?
UPC ferrules are polished at a small angle and blue in color; APC ferrules are polished at 8 degrees and green. APC gives a higher return loss, which matters for RF-over-glass and long-haul links. Never mate a UPC plug into an APC adapter - the angled surfaces grind and damage both.
Should I choose OM3, OM4 or OM5 multimode cable?
OM3 supports 10G to 300 m and 40/100G to 100 m; OM4 extends 40/100G to 150 m in most designs; OM5 adds support for short-wavelength division multiplexing. For new data center builds we quote OM4 as standard and OM5 where the design calls for it. Both come in aqua and lime jackets to your spec.
Can you make custom lengths, colors and private labels?
Yes. Lengths run from 0.3 m to 30 m for standard cords and to 100 m for outdoor duplex builds. Jacket colors include yellow, aqua, lime, violet, orange and white, and boot colors are free to mix. Your logo goes on the cable label, the bag and the carton - OEM label printing is free above 500 pieces.
How do you pack patch cords for shipping?
Each cord ships in a PE bag with a data label showing type, length and test results. Bags pack into export cartons with desiccant, and drums are used for outdoor builds above 20 m. Carton size and labels follow your instructions for direct-to-shelf distribution.
What polarity options do you offer for MPO trunks?
We build Method A, Method B and Method C polarity to your network drawing, in male and female pins, and UPC or APC polish. Tell us the cassette and port layout, and we confirm the polarity in the quotation so your panels line up end to end.
Which fiber and ferrule grades do you use?
Single-mode cords use G.652D or G.657A1/A2 fiber, multimode uses OM1 through OM5, and every ferrule is zirconia ceramic. Ferrule lots pass 3D interferometer checks on sampling, and finished cords face 100% IL and RL testing on the bench.
What happens if a cord fails in the field?
Send us the batch label and the test reading. Confirmed factory faults are replaced in the next production run at no cost, and the claim settles on data rather than opinions. Failure rates on standard cords run well under 0.1% in our shipment records (draft figure - confirm with sales).
Get Your Fiber Patch Cord Quote Today
Send your BOM - connector types, fiber grades, lengths, quantities. Your quote with prices, MOQ, lead time and packing plan arrives within 24 hours on business days. Free samples for project evaluation.
Request a Quote NowWhatsApp: +86 134 3434 9304 | Email: peter@hengxang.com
Cordons : specs, MOQ et délais
Trois chiffres décident l’essentiel des commandes : ce que nous fabriquons, combien peu il faut commander et à quelle vitesse livrer. Délais à partir de l’acompte, tests 100% inclus.
| Famille | Options | MOQ | Délai |
|---|---|---|---|
| Simplex/duplex SM | LC/SC/FC/ST, UPC/APC, 0,9-3 mm | 100 pcs | 3-6 j |
| Multimode OM1-OM5 | Duplex, aqua/lime/orange | 100 pcs | 3-6 j |
| Pigtails 0,9 mm | SC/LC/FC/ST, UPC/APC | 200 pcs | 3-5 j |
| MPO/MTP trunk | 8-72 FO, OS2/OM3/OM4, polarité A/B/C | 20 pcs | 6-10 j |
| Cordons blindés | Armure spirale, LSZH | 100 pcs | 4-7 j |
MOQ et délais standards ; pics du Nouvel An chinois +5-7 jours. Dates fixes confirmées par écrit sur la facture proforma.
Pourquoi choisir HENGXANG
- Test 100% IL/RL, mesure sur chaque étiquette.
- MOQ 100 pcs, essais bienvenus.
- Ferrules zircone uniquement, géométrie vérifiée par interféromètre.
- 10 types de connecteurs dans une même commande.
- Codage à votre marque de switch, testé sur plateforme réelle.
Questions fréquentes
Quel est votre MOQ ?
100 pièces par type pour les cordons, 200 pour les pigtails, 20 pour les MPO. Les essais sous MOQ sont acceptés pour un premier projet.
Les cordons sont-ils testés ?
Oui - 100% IL/RL sur banc, mesure sur l’étiquette et fichier de lot avec l’expédition.
UPC ou APC ?
UPC (bleu) pour le patching général, APC (vert) pour la fibre vers l’antenne et CATV. Ne jamais accoupler UPC avec APC.
Longueurs et couleurs personnalisées ?
Oui - de 0,3 à 30 m, gaine et boots à votre spec, étiquettes à votre marque dès 500 pièces.
Quelle garantie ?
Remplacement des défauts usine confirmés au lot suivant, sur preuve de test.
Demandez votre devis cordons
Types, longueurs, quantités - devis écrit sous 24 heures ouvrées, échantillons codés en 3-5 jours.
Demander un devisWhatsApp: +86 134 3434 9304 | Email: peter@hengxang.com