// Language switcher on every page: EN default navI18n unless a locale // page supplied its own. Non-translatable paths link the menu to each homepage. const navI18n = options.navI18n || (() => { const L = uiFor('en'); const m = (options.seoHeadTags || '').match(/rel="canonical" href="([^"]+)"/); const path = m ? m[1].replace(/^https?://[^/]+/, '') : '/'; const translatable = TRANSLATED_PATHS.some(re => re.test(path)); const entries = [{ code: 'en', host: 'hengxang.com', name: 'English' }, ...LOCALES]; return { t: L, currentName: 'English', path, langItems: entries.filter(e => e.code !== 'en') .map(e => '
  • ' + e.name + '
  • ').join(''), }; })();

    Fabricant de baies et armoires réseau

    HENGXANG fabrique baies et armoires réseau à Yiwu : murales 6-15U IP20, extérieures IP55 avec climatisation intégrée, battery racks extérieurs, open racks 2/4 montants et frames 1U/2U/4U.

    Tôlerie interne : CNC, pliage, poudre RAL - tailles customs sans vendor externe. Les armoires extérieures AC partent testées wired et charged.

    MOQ dès 20 pièces (extérieur) et 50 (murale/rack), flat-pack en option.

    Accueil / Produits / Network Cabinet & Open Rack

    Network Cabinet & Open Rack Products

    Cabinet Families: Specs, MOQ and Lead Time

    Every cabinet family this network-cabinet manufacturer builds is listed below with MOQ and lead time. Lead time runs from deposit and includes fit-and-finish checks before packing.

    FamilyOptionsMOQLead time
    Wall-mount cabinet6-12U, IP20 indoor, SPCC, glass or solid door50 pcs7-10 days
    Outdoor telecom cabinetIntegrated AC cooling, battery + equipment bays, IP5520 pcs12-15 days
    Outdoor battery rack19-inch, weatherproof, multi-tray battery layout20 pcs10-14 days
    Open rack 2-post / 4-post19-inch, 27-45U, data center and lab builds50 pcs6-9 days
    Server open rack1U / 2U / 4U shelf-style frames50 pcs6-9 days

    MOQ and lead-time figures are standard production windows; Chinese New Year peaks can add 5-7 days. Fixed delivery dates are confirmed in writing on the proforma invoice.

    What buyers order most from this shelf

    These five cover most purchase orders. Heights, depths, colors and lock systems are set per order by this network-cabinet manufacturer - the grid above lists the current builds.

    Wall-Mount Lineup: Sizes and Ratings at a Glance

    The wall-mount line covers the sizes buildings actually use (draft ratings - datasheets state the binding values):

    ModelUsable UDimensions (H×W×D)Static load
    6U wall cabinet6U400×600×450 mm60 kg
    9U wall cabinet9U500×600×450 mm70 kg
    12U wall cabinet12U630×600×450 mm80 kg
    15U wall cabinet15U770×600×500 mm80 kg

    Every model ships with a tempered-glass or solid door option, removable side panels, pre-punched cable entries top and bottom, and the mounting kit. Lock options run cam, quarter-turn or padlock tab.

    Sizing Guide: U Height, Depth and Load in Three Steps

    Cabinet sizing fails on guesswork. Three steps size it right:

    Send the device list and site photos, and this network-cabinet manufacturer returns the sizing sheet with the quote - U height, depth, load and cooling in writing.

    Outdoor Cabinets: Cooling, Sealing and Battery Layout

    Outdoor cabinets fail on heat and water, not on steel - and a network-cabinet manufacturer that builds and tests its own AC units says so in writing. Three engineering points decide a 10-year outdoor cabinet:

    Every outdoor cabinet ships with the cooling spec, IP rating and battery layout printed in the datasheet - and the same numbers verified in the fit test.

    Inside the Outdoor AC Cabinet: Bay by Bay

    The outdoor telecom cabinet is a small machine room, and its layout decides whether the site survives summer. Our standard layout (customizable per project):

    The cabinet ships with the AC unit fitted, wired and test-run - the compressor cycles in our shop before the crate closes. A cooling unit shipped loose in a box is a project risk, not a component.

    Wall-Mount Installation: Six Steps, One Person, Fifteen Minutes

    A wall cabinet is a two-person lift but a one-person install. The sequence our instruction card prints:

    1. Mark and drill: hold the shell level, mark four anchors, drill to the wall type - the template ships in the box.
    2. Hang: lift onto the anchors with a second pair of hands for the lift only.
    3. Bring cables in: feed through the top or bottom entry, clamp the gland.
    4. Mount the gear: rack the devices on the tapped rails with cage nuts or the supplied screws.
    5. Manage the cabling: dress cords through the rings, leave the service loops coiled.
    6. Ground and close: bond the grounding lug, fit the door, lock it - and photograph the port numbers for the record.

    Wall cabinets mount onto brick, block and stud walls; the anchor type ships to match the wall you state in the RFQ.

    Outdoor Siting: Four Choices That Outlive the Warranty

    An outdoor cabinet forgives a bad wall, not a bad seat. Four siting choices decide the service life:

    Site photos travel with the RFQ, and the quote confirms the bracket, plinth and drainage accessories for that exact spot.

    Build Quality: Steel, Seams and Coating, Measured

    Cabinet steel looks identical in photos. Three measurements separate a ten-year frame from a three-year one:

    Ask any supplier for the three numbers - panel thickness, seam type, coating microns. A network-cabinet manufacturer that runs its own sheet-metal line answers from the shop floor, not from a catalog.

    OEM, ODM and Private-Label Capability

    As an OEM network-cabinet manufacturer with in-house tooling, we build to your size, color and layout:

    OEM projects we shipped (draft references - replace with your approved cases)

    “The AC units pulled the batteries down to spec on a 45-degree day - our old cabinets never managed that.” - site rollout lead, Middle East operator (draft testimonial - replace with your approved reference).

    “Flat-pack racks assembled in 15 minutes each, and 450 of them fit in two containers. The freight math sold the project.” - operations manager, data center builder (draft testimonial - replace with your approved reference).

    Cabinets ship filled or empty: buyers commonly pre-load them with our splitter cassettes, termination boxes, patch cords and adapters - the whole site kit lands in one container.

    Thermal Management: The Numbers Behind the Fans

    Heat kills electronics slowly and silently. Indoor cabinet cooling is a calculation, not an accessory choice:

    For outdoor builds the same math picks between fans, heat exchangers and AC - each step up in cooling capacity costs capex and power. The quote states the load we sized the cooling for, so the site math stays on record.

    Wholesale Program for Distributors and Rollout Teams

    Cabinets are bulky, so the wholesale program here prices logistics as carefully as steel:

    Distributors typically start with a mixed trial container and move to call-off terms once the freight math and field returns prove out.

    Certifications and Compliance

    The factory runs under ISO 9001:2015, with CE reports covering passive and cabinet families sold into the EU, and the company holds a utility patent on a fiber optic quick connector - the in-house R&D behind our passive range. Documents are public on the certificate page.

    CertificateRelevance to cabinets
    ISO 9001:2015Quality management for fabrication, coating and assembly
    OHSAS 18001:2007Occupational health and safety management
    CE reportsCabinet and passive families shipped into the EU
    Utility model patentQuick connector design - the factory's R&D depth

    Steel thickness certificates, salt-spray test notes on outdoor coatings (draft - confirm current reports) and RoHS statements join the quote on request.

    Factory Strength: The Sheet-Metal Line Behind Every Cabinet

    Cabinet quality starts at the press brake, and this network-cabinet manufacturer owns the press brake. The Yiwu compound runs CNC punching, bending, welding and powder coating beside our fiber production - 25 years under founder LING LI, since December 2000:

    Company quick facts
    FoundedDecember 2000, Yiwu City, Zhejiang, China
    FounderLING LI, Founder & General Manager
    FocusCabinets, ODFs, splitters, boxes, connectors, adapters, patch cords, pigtails, cable
    Export markets40+ countries across Asia, the Middle East, Africa, Europe and the Americas
    Response timeQuotes within 24 hours on business days

    Why Buyers Pick HENGXANG Over Other Suppliers

    Cabinet quotes look alike until the first summer and the first container. Compare on the points that decide both:

    FactorHENGXANGTypical trading company
    ToolingIn-house molds and presses - custom sizes run in normal lead timeOutsourced tooling, long custom cycles
    Outdoor coolingAC integrated, tested wired and charged before packingCooling unit loose in the box
    FreightFlat-pack line standard; mixed containers with fiber goodsAssembled-only, half-empty containers
    MOQ20-50 pcs by family100+ pcs minimums
    Quote speedWithin 24 hours on business daysDays
    RangeCabinets + ODFs + splitters + cords, one orderSingle category

    And one habit worth naming: we quote the container plan with the cabinet plan. A cabinet that halves your container count is worth more than a cabinet that saves a dollar.

    How We Work With You: From Site List to Loaded Containers

    Six steps, all written down:

    Worked Example: A 200-Cabinet District Program

    Illustrative figures - your quote states yours. An ISP equips 200 street sites: 120 outdoor AC cabinets and 80 wall-mount riser cabinets:

    StepDetail
    Day 0Site list received; cabinet schedule and container plan returned next morning
    Day 1-4Samples airfreighted - one AC cabinet, one wall cabinet - for site pilots
    Day 5-14Production: AC units integrated and test-run; wall cabinets flat-packed
    Day 14-15Fit checks on 10 sampled units per model; photos shared live
    Day 16-17Container plan: AC cabinets assembled on pallets, wall cabinets flat-packed - 4 containers total
    Day 18Trucked to Ningbo, FOB; documents within 3 working days of sailing

    Eighteen days from site list to four sealed containers - and the pilot sites were already live while the containers loaded. That is the schedule a network-cabinet manufacturer with its own sheet-metal line can sign.

    House the Network, Then Run the Whole Shelf

    Cabinets house the network, and this network-cabinet manufacturer ships everything that goes inside: the ODFs for the exchange racks, the splitter cassettes for the distribution shelves, the termination boxes beside the cabinets, the patch cords on the ports, the adapters, the transceivers in the switches, and the cable on the route. Level trouble at the receivers? Attenuators trim it. One purchase order, one freight plan, one warranty conversation - the whole site from one network-cabinet manufacturer that also makes the fiber inside it.

    Locks, Security and Grounding: The Quiet Specs

    Three quiet specs decide whether a cabinet stays safe and legal for a decade:

    Security and earthing spec lines appear on every quotation - a network-cabinet manufacturer that stays silent on grounding is asking the field to improvise it.

    Inside the Cabinet: Cable Entries and Management

    A cabinet's rear tells the truth about its design. Three build details keep the inside ordered for years:

    Pre-punched entries ship sealed with knock-out covers. Every entry you state in the RFQ arrives open and glanded; the rest arrive sealed.

    Wall Cabinet, Floor Cabinet or Open Rack? The Right Frame per Site

    Three frames, three site profiles. The comparison our application desk runs with buyers:

    Wall-mount cabinetFloor cabinetOpen rack
    Best siteCorridors, small offices, camera headsEquipment rooms, street sites (outdoor)Labs, data center rows
    Capacity6-15U, 60-80 kg18-42U, 800-1,200 kg27-45U, 500-800 kg
    SecurityLockable door, wall-fixedLockable, anchorable, outdoor IP optionsOpen by design
    AirflowVent + optional fan trayFan tray or AC (outdoor)Open natural airflow
    Choose it whenSpace is tight and gear is smallGear is heavy, public, or outdoorAccess speed beats appearance

    Most projects order two of the three: wall cabinets at the edges, floor cabinets or racks at the core. One order, one container, one hardware standard across the site.

    Accessories: Fill the Cabinet From the Same Container

    PDU planning rides with the accessories: state the equipment wattage and plug types, and the quote fits the outlet count and breaker size per cabinet. These accessories share the cabinet container and the price tier - a site kit leaves the factory as one labeled set per cabinet, PDUs installed and tested.

    Maintenance: A Cabinet Checklist That Takes Five Minutes

    Twice a year, walk the cabinet with this five-line checklist:

    Every point above takes a minute. Together they keep a ten-year cabinet on its ten-year plan - the maintenance habit this network-cabinet manufacturer prints on every instruction card.

    Frequently Asked Questions

    Can cabinets ship pre-loaded with our fiber equipment?

    Yes - as a fiber optic factory we load ODF panels, splitter cassettes, termination boxes and patch cords into the cabinets at our own benches, test every port, and label them to your site plan. The cabinet arrives as a finished distribution point, and the field crew mounts it and plugs in. Loaded cabinets ship in 8-12 days depending on the config.

    How do I size the cabinet - how many U do I need?

    List every device with its rack height in U, add the patch panels and PDU space, then add 20-30% spare for growth. A typical branch site runs 12-18U of active gear inside a 22U wall cabinet. Send the device list and this network-cabinet manufacturer returns the U count and the recommended model.

    What load can your cabinets and racks hold?

    Wall-mount cabinets carry 60-80 kg static load depending on size; floor cabinets hold 800-1,200 kg static on adjustable feet; open racks hold 500-800 kg. Dynamic load ratings for transport are lower - the datasheet states both numbers per model.

    What is the difference between IP20 and IP55 cabinets?

    IP20 indoor cabinets protect against touch and falling objects - standard for offices and equipment rooms. IP55 outdoor cabinets seal against dust and water jets, with gasketed doors, sealed glands and often active cooling. Outdoor gear belongs in IP55 or better - indoor rating fails within one season outside.

    How do outdoor cabinets handle heat?

    Three ways, by heat load: passive ventilation for small loads, heat exchangers for sealed mid-load builds, and compressor AC for high-density battery or telecom loads. Our outdoor telecom cabinet carries an integrated AC unit sized to the battery and equipment layout - state the equipment wattage and we size the cooling in the quote.

    What is your MOQ for cabinet orders?

    Wall-mount and open racks start at 50 pieces, outdoor telecom and battery cabinets at 20 pieces. Mixed models share one container. Custom colors and lock systems run from the same MOQ - the tooling lives in-house.

    How long does a cabinet order take?

    Wall-mount and open racks ship in 7-10 days; outdoor AC cabinets in 12-15 days because the cooling unit integrates and tests into the build. Flat-pack orders pack lighter and ship on the same windows. Every cabinet passes a fit-and-finish check before packing.

    Can cabinets ship flat-packed?

    Yes. Floor cabinets and open racks ship flat-packed with assembly hardware and instructions - a two-person crew assembles one in about 15 minutes. Flat-pack triples the units per container versus assembled cabinets, and the freight saving usually outweighs the assembly labor.

    What grounding and locking options are available?

    Every cabinet ships with grounding lugs and an earthing point; metal doors take cam locks, quarter-turn locks or padlock tabs. Keyed-alike lock sets across a whole order run as an option - state it in the RFQ and the keys arrive numbered.

    Get Your Network Cabinet Quote Today

    Send your cabinet list - indoor or outdoor, sizes, cooling, colors, quantities. Your quote with prices, MOQ, lead time and the container plan arrives within 24 hours on business days. Free samples for site fit checks. Custom colors, lock sets and pre-loaded configs all run from the same in-house tooling - one factory, one lead time, one accountable contact.

    Request a Quote Now

    WhatsApp: +86 134 3434 9304  |  Email: peter@hengxang.com

    Baies : specs, MOQ et délais

    Trois chiffres décident l’essentiel des commandes : ce que nous fabriquons, combien peu il faut commander et à quelle vitesse livrer. Délais à partir de l’acompte, tests 100% inclus.

    FamilleOptionsMOQDélai
    Murale IP206-15U, SPCC, porte vitrée ou pleine50 pcs7-10 j
    Extérieure telecom ACIP55, bay équipement + batterie20 pcs12-15 j
    Battery rack extérieur19’, multi-trays, weatherproof20 pcs10-14 j
    Open rack 2/4 montants27-45U, data center et lab50 pcs6-9 j
    Server frame 1U/2U/4UMontage individuel50 pcs6-9 j

    MOQ et délais standards ; pics du Nouvel An chinois +5-7 jours. Dates fixes confirmées par écrit sur la facture proforma.

    Pourquoi choisir HENGXANG

    Questions fréquentes

    Quelle hauteur en U ?

    Listez chaque équipement en U, ajoutez panneaux et PDU, puis 25% de marge - un équipement de 14U veut une baie 18-22U.

    Quelle charge supportée ?

    Murales 60-80 kg, au sol 800-1 200 kg statique, open racks 500-800 kg (valeurs types - datasheets par modèle).

    IP20 ou IP55 ?

    IP20 intérieur ; extérieur IP55 minimum avec gaskets, glands et drainage - les équipements d’extérieur ne rentrent jamais dans de l’IP20.

    Refroidissement extérieur ?

    Ventilation passive, échangeur ou clim intégrée selon la charge thermique - l’unité AC est testée wired et charged avant expédition.

    Flat-pack ?

    Oui - baies démontées avec quincaillerie, montage ~15 min à deux, ~3× plus d’unités par conteneur.

    Demandez votre devis baies et armoires

    Intérieur/extérieur, tailles, cooling, couleurs, quantités - devis et plan conteneur sous 24 heures ouvrées.

    Demander un devis

    WhatsApp: +86 134 3434 9304  |  Email: peter@hengxang.com

    Contact By Whatsapp