Fabricant de coffrets de raccordement
HENGXANG moule et équipe des coffrets de raccordement à Yiwu : intérieur ABS 8-16 cœurs, extérieur IP55/IP65 avec slot splitter, boîtiers métal et modules cassettes MPO.
Coffrets livrés vides ou pré-équipés : adaptateurs, pigtails et manchons montés et testés en usine - le chantier se limite à monter et brancher.
MOQ dès 200 pièces, pré-équipés dès 8-10 jours.
Fiber Termination Box Products
Box Families: Specs, MOQ and Lead Time
Every box family this fiber termination box manufacturer molds and assembles is listed below with MOQ and lead time. Lead time runs from deposit and includes gasket fitting, adapter insertion and 100% port testing on pre-loaded builds.
| Family | Options | MOQ | Lead time |
|---|---|---|---|
| Indoor wall-mount ABS | 8 / 16 core, SC or LC panel, white or custom | 200 pcs | 6-9 days |
| Outdoor waterproof IP55/IP65 | 16 core, splitter slot, round cable glands | 200 pcs | 6-9 days |
| Metal terminal box | Simplex, indoor equipment-side termination | 200 pcs | 7-10 days |
| MPO/MTP cassette module | 12 port, OM3/OM4/OS2, polarity to spec | 100 pcs | 6-9 days |
| Pre-loaded builds | Adapters + pigtails + sleeves fitted and tested | 200 pcs | 8-10 days |
MOQ and lead-time figures are standard production windows; Chinese New Year peaks can add 5-7 days. Fixed delivery dates are confirmed in writing on the proforma invoice.
What buyers order most from this shelf
- 16-core outdoor IP65 with splitter slot: the FTTH distribution point - drop cables out, splitter inside, everything sealed.
- 16-core indoor white wall-mount: building riser terminations and home entry points.
- 8-port patch panel style: small offices and apartment risers.
- MPO/MTP 12-port cassettes: data center racks pairing with our splitter cassettes.
- Metal simplex boxes: equipment-side terminations near OLT racks.
These five cover most purchase orders. Adapter layouts, colors and pre-load configs are set per order - the grid above lists the current shell builds.
Anatomy of a Termination Box: Five Parts That Do the Job
Buyers who know the five working parts also know why prices differ between suppliers:
- Shell and gasket: flame-retardant ABS indoors, UV-stabilized PC outdoors, with an EPDM gasket that makes the IP rating real. A gasket is cheap; a return visit to a flooded box is not.
- Cable glands: sealed entries that clamp the cable on its strength member - water runs down the outside, never inside.
- Splice tray: holds the fusion joints with bend-radius control and 60 mm of stored slack per joint.
- Adapter panel: SC or LC, UPC or APC, swappable after purchase - the customer-facing half of the link.
- Splitter slot (outdoor models): a rated space for a 1x8 or 1x16 mini PLC, turning the box into a small distribution point.
Five parts, five specs - and all five are stated line by line in our quotation, so procurement compares boxes by construction instead of by photo. That is the quoting habit of a fiber termination box manufacturer that molds its own shells.
Adapter Panel Layouts: Choose by Port Count and Type
The adapter panel is the customer-facing half, and it configures per order:
| Panel layout | Ports | Common use |
|---|---|---|
| SC simplex single row | 8 / 12 / 16 | FTTH home and riser boxes |
| SC duplex pairs | 4 / 8 | Small office equipment links |
| LC quad high-density | 16 / 24 | Dense riser frames |
| Hybrid zones | SC + LC mixed | Migration networks running two types |
| Splitter combo | 8-16 adapters + mini PLC slot | Outdoor distribution points |
Panel swaps need no tools and no glue - adapters click into the cutouts from the front. A box ordered for SC today reconfigures to LC or APC in minutes, which is why we quote panels and shells as separate lines.
Indoor or Outdoor? Choose by IP Rating, Not by Guess
The fastest way to pick a box is to answer where it lives:
| Location | Recommended family | Spec points |
|---|---|---|
| Home or office interior wall | Indoor ABS 8-16 core | Flame-retardant shell, clean white finish |
| Stairwell or shared riser | Indoor ABS 16 core + lock option | Larger tray for multiple drops |
| Building exterior under eaves | Outdoor IP55 | UV-stable shell, drainage slot |
| Pole or street-level cabinet | Outdoor IP65 + splitter slot | Full gasket, sealed glands, shrapnel adapters |
| Equipment rack at the OLT | MPO/MTP cassette or metal box | Rack ears, front access, test-grade adapters |
When the location sits between two ratings, we quote the tougher one. Waterproofing failures cost more in truck rolls than the price step costs at the factory.
Outdoor Box Spec Points: What "Waterproof" Must Mean
Outdoor boxes earn their rating from six construction details. Our IP65 builds specify all six, and the quote lists them:
- Lid gasket: EPDM, full-perimeter, in a groove - not surface glue.
- Cable glands: clamping glands with sealing rings sized to the cable - one gland per entry, all entries used or plugged.
- Drainage: a weep slot at the bottom, because condensation finds its way into every outdoor housing.
- Shell: UV-stabilized PC or ABS - a shell that chalks in year two was never outdoor grade.
- Hinge and latch: stainless hinge pin, snap latch with an optional padlock tab.
- Internal layout: splitter slot, splice tray and adapter zone separated - water that enters one zone cannot wick into another.
Ask any supplier for the same six lines. Boxes that pass a hose test in year one and leak in year three skipped one of them - usually the gasket groove.
Cable Entries: Gland Sizing and Entry Layout
Cable entry is where outdoor boxes win or leak. Our entry plan ships like this (draft - per-model drawings state the exact sizing):
| Entry | Accepts | Typical use |
|---|---|---|
| Bottom gland 1 | 8-12 mm round distribution cable | Feeder from the closure |
| Bottom gland 2 | Flat drop 2×3 mm, up to 4 pieces | Customer drops out to the homes |
| Side knockouts | 5.5 mm glands or blank plugs | Spare entries for future splits |
Bottom entry keeps water running past the box instead of into it; the gland clamps the strength member so the fiber never takes the pull. Unused entries ship with sealed plugs - an open knockout is a water door.
Empty or Pre-Loaded: The Decision That Saves Field Days
Two buying styles, two honest trade-offs:
| Empty box | Pre-loaded box | |
|---|---|---|
| Ships with | Shell, tray, adapter panel of your choice | Adapters, pigtails, sleeves - fitted and tested |
| Field work per box | Splice, fit adapters, test | Mount, plug drops, label |
| Best for | Teams with jointers on every site | Rollouts on schedule and tight labor |
| Freight | Lighter | Slightly heavier, same carton counts |
Pre-loaded boxes arrive with every port reading on a test sheet, numbered to match your drop plan. Rollout teams that switch to pre-loaded typically cut installation time per home by a third (draft figure - confirm in your pilot). Empty boxes stay on the shelf for crews who splice everything anyway.
Installation: Twenty Minutes From Carton to Live Ports
A first-time crew follows this sequence - it is the same order our own pre-load line uses, minus the factory test:
- Mount: mark the anchors, drill, and screw the box to the wall or bracket. Outdoor boxes hang on the integrated bracket first, then bolt flat.
- Bring the cable in: feed the cable through the gland, clamp the strength member to the internal anchor, and tighten the gland - water stops at this gland, so tight matters.
- Splice or terminate: fusion-splice pigtails in the tray for outdoor builds, or fit fast connectors for indoor drops. Slack coils in the tray at 60 mm minimum radius.
- Seat the adapters: snap SC or LC adapters into the panel cutouts and connect the drop cords.
- Label and close: number the ports to the drop plan, test each port with a meter, close the lid - gasket seated, screws torqued.
Boxes arrive with the mounting kit in the carton: anchors, screws, gland sets and a packing of tie wraps. The instruction card prints the sequence above in five languages.
OEM, ODM and Private-Label Capability
As an OEM fiber termination box manufacturer, we build to your colors, port layout and label spec:
- OEM: laser marks and private-label bags from 500 pieces; custom shell colors from 500 pieces per color - the molds live in-house.
- ODM: new port layouts, splitter-slot sizes and mounting brackets as drawing projects - samples in 10-15 days after approval (draft).
- OBM / JDM: exclusive models and stocked programs for distributors under NDA, with seasonal price locks.
OEM projects we shipped (draft references - replace with your approved cases)
- Middle East FTTH program, 2024: 25,000 IP65 16-core boxes with SC/APC adapters pre-loaded, green shells, phased across a two-season rollout.
- European ISP, 2023: 12,000 indoor 16-core white boxes with lockable lids for shared stairwells, private-label marked.
- Latin American installer, 2025: 6,000 boxes pre-fitted with 1x8 splitters for zero-splice district rollouts.
“The gasket and gland seals passed our hose test on the first batch. We stopped site-inspecting boxes after that.” - rollout supervisor, Middle East FTTH program (draft testimonial - replace with your approved reference).
“Pre-loaded boxes cut our per-home install from 40 minutes to 25. The schedule caught up in two weeks.” - operations lead, Latin American installer (draft testimonial - replace with your approved reference).
Boxes usually ship together with the splitters that sit inside them, the adapters on the panel, and the pigtails behind the adapters - one container, one supplier, one warranty conversation.
Wholesale Program for Distributors and Rollout Teams
Boxes arrive in project waves, so the wholesale program at this fiber termination box manufacturer runs on scheduling:
- Mixed-model orders: indoor, outdoor and cassette models share one container and one price tier.
- Call-off stocking: frame agreements reserve production slots against your district calendar.
- Pre-loaded phasing: loaded boxes build to your drop plan, labeled per district.
- Price protection: 30-day holds on quoted project prices.
- Tender pack: certificates, IP test notes and product photos for your bid file.
New distributors start with a mixed trial order and move to call-off terms once the field failure rate shows itself - our field rate is the argument, and the test sheets are the proof.
Regional Notes: Boxes Ship Differently by Market
Twenty-five years of export taught this fiber termination box manufacturer how markets tune the same box:
- Asia-Pacific: white indoor boxes with SC/UPC panels lead; outdoor builds add shutter adapters for street cabinets.
- Europe: lockable lids for shared stairwells, LSZH-flavored materials on request, and private-label retail packs for DIY channels.
- Middle East & Africa: IP65 outdoor builds with metal shrapnel adapters, green APC panels, and pole-mount brackets as standard.
- Americas: compact 8-core home boxes in customer colors, blister-ready packaging for retail shelves.
Tell us the country and the mounting point. We answer with the build that already ships there.
Certifications and Compliance
The factory runs under ISO 9001:2015, with CE reports covering passive families sold into the EU, and the company holds a utility patent on a fiber optic quick connector - the R&D depth behind our pre-loaded assemblies. Documents are public on the certificate page.
| Certificate | Relevance to termination boxes |
|---|---|
| ISO 9001:2015 | Quality management for molding, assembly and port testing |
| OHSAS 18001:2007 | Occupational health and safety management |
| CE reports | Passive families shipped into the EU |
| Utility model patent | Quick connector design - the factory's R&D depth |
Shell materials run RoHS-compliant and flame-retardant to UL94 V-0 on indoor models (draft claim - confirm current material certificates). IP seal verification runs on sampled batches with a water-jet test rig.
Factory Strength: Our Own Molds, Our Own Bench
Box quality lives in the mold and the gasket groove, so this fiber termination box manufacturer keeps both in-house. The Yiwu compound molds shells, fits gaskets, loads adapters and tests ports beside our cable and cord lines - 25 years under founder LING LI, since December 2000:
- Molding: in-house injection tools for every shell on the shelf; color and material changes run without a tooling vendor.
- Assembly: gaskets, glands, trays and panels fitted by fixture; screws torqued, not guessed.
- Pre-load line: adapters seated, pigtails spliced, sleeves fitted - then every port reads IL and RL on the bench before the lid closes.
- Quality: Grace Xu, Quality Director, releases batches against the IP seal test and port readings.
- Export: Peter Lin, Head of Export Sales - one contact for quotes, production photos and documents. Video audits run any business day - see the factory gallery.
| Company quick facts | |
|---|---|
| Founded | December 2000, Yiwu City, Zhejiang, China |
| Founder | LING LI, Founder & General Manager |
| Focus | Termination boxes, splitters, connectors, adapters, patch cords, cable, ODFs |
| Export markets | 40+ countries across Asia, the Middle East, Africa, Europe and the Americas |
| Response time | Quotes within 24 hours on business days |
Why Buyers Pick HENGXANG Over Other Suppliers
Boxes look identical in a catalog. Compare on the details that fail in the field:
| Factor | HENGXANG | Typical trading company |
|---|---|---|
| IP sealing | Gasket + gland spec stated in writing; sampled water-jet tests | "Waterproof" - unspecified |
| Pre-load testing | 100% port IL/RL on loaded builds, sheet in the box | No port data |
| Molds | In-house - custom colors and layouts run fast | Outsourced molding |
| MOQ | 100-200 pcs by family | 1,000 pcs minimums |
| Quote speed | Within 24 hours on business days | Days |
| Range | Boxes + splitters + adapters + cords, one container | Single category |
And one habit worth naming: we ask what mounts behind the box before quoting adapter counts. A 16-core box with 24 planned homes needs a splitter slot, not more adapters - and we would rather fix the BOM than ship the wrong box.
How We Work With You: From Site List to Delivered Cartons
Six steps, all written down:
- Step 1 - RFQ: send the box list - indoor or outdoor, cores, adapter types, pre-load preference. WhatsApp +86 134 3434 9304 or the contact form.
- Step 2 - Quote: prices, MOQ, lead time and packing plan within 24 hours on business days.
- Step 3 - Samples: sample boxes ship in 3-5 days for a site fit check.
- Step 4 - Production: photos at molding, assembly and pre-load test stages while your order runs.
- Step 5 - Inspection: IP seal sampling, port test sheets, third-party inspection on request.
- Step 6 - Shipment: EXW, FOB Ningbo/Shanghai or CIF; documents within 3 working days of sailing.
Worked Example: A 2,000-Box District Rollout
Illustrative figures - your quote states yours. An ISP rolls fiber across 2,000 homes: 1,200 outdoor IP65 16-core boxes pre-loaded with 1x8 splitters and SC/APC adapters, plus 800 indoor white boxes empty:
| Step | Detail |
|---|---|
| Day 0 | Mixed RFQ received; quote issued next morning - pre-load BOM confirmed per district |
| Day 1-3 | Sample outdoor and indoor boxes airfreighted for site fit checks |
| Day 4-11 | Molding and assembly; pre-load line splices and tests the 1,200 loaded builds |
| Day 11-12 | IP water-jet sampling on the outdoor batch; port sheets filed per box serial |
| Day 13 | Carton pack, district-labeled; ~26 cbm total, one 40 ft container |
| Day 14 | Trucked to Ningbo, FOB; documents within 3 working days of sailing |
Fourteen days from site list to sealed container, with 1,200 boxes ready to mount and connect. That is the schedule a fiber termination box manufacturer with its own molds and pre-load bench can sign.
Worked Example: A 500-Box Mixed Order, Carton to Curb
Illustrative figures - your quote states yours. An installer mixes models for one district: 300 outdoor IP65 16-core pre-loaded with SC/APC adapters, and 200 indoor white 8-core empty boxes:
| Step | Detail |
|---|---|
| Day 0 | RFQ received; quote issued next morning with the pre-load BOM per district |
| Day 1-3 | Samples airfreighted - one outdoor, one indoor - for a site fit check |
| Day 4-9 | Molding run; pre-load line splices and tests the 300 loaded builds |
| Day 9-10 | IP water-jet sampling on the outdoor shells; port sheets filed per serial |
| Day 11 | Carton pack: 300 loaded boxes district-labeled, 200 empty boxes in master cartons |
| Day 12 | Trucked to Ningbo, FOB; documents issued 2 days after sailing |
Twelve days from RFQ to a sealed container, with the loaded boxes labeled per district and the empty boxes packed for the crew's own splicing day. That is the logistics a fiber termination box manufacturer with in-house molds and a pre-load bench can sign in writing.
Termination Box, Splice Closure or ODF? The Right Hardware per Point
Three hardware types guard fiber joints, and projects need all three in the right places. The short version from our application desk:
| Termination box | Splice closure | ODF | |
|---|---|---|---|
| What it holds | Adapters for live drop ports + a small splice tray | Splice joints only - no adapters | High port counts on a rack frame |
| Where it mounts | Walls, building entries, drop points | Poles, pedestsals, underground chambers | 19-inch racks in exchanges |
| Ports | 8-16 | Joint capacity, not adapter ports | 24-96 per frame |
| Pick it when | The cable ends and drop cords begin | Cable runs join mid-route | Many cables aggregate in one room |
A typical FTTH chain uses all three: the closure joints the feeder mid-route, the termination box serves the building, and the ODF anchors the exchange. We build all three - see the splice closure range and the ODF range for the other two roles.
Accessories ship with every box order: wall anchors and screws, gland sets per entry, dust caps for open adapters, and label sheets for port numbering. Splice sleeves, pigtails and adapters order as line items when you want the box pre-loaded.
Quality stands behind the schedule: shells carry a two-year replacement warranty against mold or material faults (draft term - confirm on the proforma), gaskets stock as spare parts for your maintenance kits, and every pre-loaded port test sheet stays on file for the same period. Hardware this durable should come with paperwork that lasts just as long.
Close the Drop, Then Run the Whole Shelf
The termination box ends the cable run, and the same factory ships everything that feeds it: the drop and distribution cable, the splitters that sit in the box slot, the connectors and adapters on the panel, the pigtails and patch cords behind the wall, and the splice closures and ODFs up the chain. Crews finishing drops with no splicer take our fast connectors; the exchange side runs our attenuators when links run hot. Planning the exchange? Start with the ODF planning guide. One purchase order, one freight plan, one warranty conversation.
Frequently Asked Questions
What is a fiber termination box used for?
It houses the point where an outdoor or riser cable ends and customer patch cords begin. Inside are a splice tray for the joint, adapter ports for the drops, and storage loops for slack fiber. The box protects those joints from dust, water and pulling force - the three things that kill a fiber.
What is your MOQ for fiber termination box orders?
Standard indoor and outdoor boxes start at 200 pieces per model, and MPO/MTP cassette modules at 100 pieces. Mixed colors and adapter layouts share one production run. Pre-loaded boxes - adapters, pigtails and sleeves factory-fitted - start at 200 pieces per configuration.
What does IP55 or IP65 mean on an outdoor box?
The IP code rates sealing against dust and water. IP55 blocks dust and low-pressure jets; IP65 is fully dust-tight and withstands stronger water jets. For wall boxes under eaves, IP55 is common; for pole-mounted or street-level boxes, we quote IP65 with a gasketed lid and sealed cable glands.
Should I order boxes empty or pre-loaded?
Empty boxes ship with the adapter panel only, and your crew splices and fits adapters on site. Pre-loaded boxes arrive with adapters, pigtails and sleeves factory-installed and tested - installation becomes mounting the box and plugging in. Pre-loaded cuts field labor; empty cuts freight and lets your team standardize on site.
Which adapters and splitters fit inside?
Standard builds carry SC or LC adapters in UPC and APC, and the 16-core outdoor models hold a 1x8 or 1x16 mini PLC splitter in the dedicated slot. Adapter panels swap after purchase, so a box ordered for SC today converts to LC without tools.
How is the box installed?
Indoor boxes mount with two or four wall anchors; outdoor boxes add a hanging bracket for poles and sealed cable glands for entry. Inside, the cable clamps on the strength member, slack fiber coils in the tray, and drops exit through the bottom glands. A first box takes a technician about 20 minutes including splices.
Can I order custom colors, sizes or private labels?
Yes. Shell colors run from standard white and black to custom shades from 500 pieces per color. Laser marks and private-label bags start at 500 pieces, and ODM sizes or port layouts run as drawing projects with samples in 10-15 days (draft). The factory owns its molds, so custom work stays in-house.
What material are the boxes made of?
Indoor shells use flame-retardant ABS; outdoor shells use UV-stabilized PC or ABS rated for -40 to +70 degrees C service. Gaskets are EPDM, and screws are galvanized or stainless. Material certificates are available with the shipment on request.
Maintenance: Two Minutes a Year per Box
Termination boxes are quiet hardware, but an annual glance keeps them honest - advice this fiber termination box manufacturer prints on every instruction card: wipe the adapter dust caps, re-seat any loose drop, check the gland clamp after storm season, and confirm the lid gasket sits flat. Ports that read dirty get a one-click cleaner on both ends - the box was never the problem. Indoor boxes need nothing beyond the adapter clean, and outdoor boxes need the gasket glance. That is the whole maintenance manual.
Get Your Fiber Termination Box Quote Today
Send your box list - indoor or outdoor, core counts, adapter types, pre-load preference. Your quote with prices, MOQ, lead time and packing plan arrives within 24 hours on business days. Free samples for site fit checks.
Request a Quote NowWhatsApp: +86 134 3434 9304 | Email: peter@hengxang.com
Coffrets : specs, MOQ et délais
Trois chiffres décident l’essentiel des commandes : ce que nous fabriquons, combien peu il faut commander et à quelle vitesse livrer. Délais à partir de l’acompte, tests 100% inclus.
| Famille | Options | MOQ | Délai |
|---|---|---|---|
| Intérieur mural ABS | 8 / 16 cœurs, SC ou LC | 200 pcs | 6-9 j |
| Extérieur IP55/IP65 | 16 cœurs + slot splitter 1x8/1x16 | 200 pcs | 6-9 j |
| Boîtier métal | Simplex, côté équipement | 200 pcs | 7-10 j |
| Cassette MPO/MTP | 12 ports, OM3/OM4/OS2 | 100 pcs | 6-9 j |
| Pré-équipés | Adaptateurs + pigtails + manchons testés | 200 pcs | 8-10 j |
MOQ et délais standards ; pics du Nouvel An chinois +5-7 jours. Dates fixes confirmées par écrit sur la facture proforma.
Pourquoi choisir HENGXANG
- Mouls internes : couleurs et layouts sans vendor externe.
- Joint EPDM périmétrique + presse-étoupes - l’IP65 est construit, pas déclaré.
- Pré-équipés testés port par port, fiche dans le coffret.
- Slot splitter pour 1x8/1x16 mini PLC.
- Adaptateurs swap sans outil : SC vers LC en minutes.
Questions fréquentes
À quoi sert un coffret de raccordement ?
À protéger la transition entre le câble extérieur et les cordons d’abonné : épissures, adaptateurs et boucles de sécurité dans un boîtier scellé.
IP55 ou IP65 ?
IP55 sous abri, IP65 pour poteau et pleine exposition - joint périmétrique et presse-étoupes sur les deux.
Vide ou pré-équipé ?
Vide pour vos équipes d’épissage ; pré-équipé (adaptateurs + pigtails testés) pour économiser un tiers du temps de chantier.
Quel slot splitter ?
1x8 ou 1x16 mini PLC en cassette - le modèle 16 cœurs l’accepte d’origine.
Matériaux ?
ABS ignifuge intérieur, PC stabilisé UV extérieur, joint EPDM, vis galvanisées - certificats sur demande.
Demandez votre devis coffrets
Intérieur/extérieur, cœurs, adaptateurs, pré-équipement - devis écrit sous 24 heures ouvrées.
Demander un devisWhatsApp: +86 134 3434 9304 | Email: peter@hengxang.com